LMG Accessories

LMG600 Accessories
Software |
|
Order No. | Description |
Software |
|||
Order No. |
|
||
L6-OPT-DRV |
Option package for frequency converters for LMG600 (at least 3 power channels*), consisting of: - L6-PSI: Process Signal Interface - L6-SDC: Star-Delta-Conversion - L6-HRM: Harmonic analysis up to max. 400th order (2.000th order with interharmonics) |
||
L6-OPT-TRAFO |
Option package for transformers for LMG600 (at least 3 power channels*), consisting of: - L6-SDC: Star-Delta-Conversion - L6-HRM: Harmonic analysis up to max. 400th order (2.000th order with interharmonics) - Custom specific menu, programmed with the arithmetic mean of Utrms and Itrms and the corrected output value Pc (Pc specified by the customer!) |
||
L6-OPT-CE-FLK |
Option Package CE Flicker for LMG600, consisting of: - the LMG flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as - the PC software** LMG Test Suite (LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-3 and EN61000-3-11 for 1-phase and 3-phase* equipment under test |
||
L6-OPT-CE-HRM |
Option Package CE Harmonics for LMG600, consisting of: - the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM) as well as - the PC software** LMG Test Suite (LMG-TEST-CE-HRM) for analysis of measured values according to EN61000-3-2 and EN61000-3-12 for 1-phase and 3-phase* equipment under test |
||
L6-OPT-CE-HRMFLK |
Option Package CE Harmonics and Flicker for LMG600, consisting of: - the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM), - internal flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as - the PC software** LMG Test Suite (LMG-TEST-CE-HRM + LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-2 / EN61000-3-12 and EN61000-3-3 / EN61000-3-11, each for 1-phase and 3-phase* equipment under test |
||
L6-OPT-DVI |
DVI / VGA Interface for connection of an external display, beamer, touch device |
||
L6-OPT-PSI |
Process Signal Interface 8 digital inputs, 8 digital outputs, 2 fast analog inputs (150 kS/s, 15 kHz bandwidth), 8 slow analog inputs (DC), 32 analog outputs, 2 frequency inputs (frequency, orientation, position; DTL, HTL or differential) |
||
L6-OPT-CAN |
CAN bus interface:
find more information here CAN bus connectivity according to ISO 11898-2 (high-speed CAN) - bit rate: 5 kbit/s to 1Mbit/s - galvanic separation at CAN connector: up to 500V - active support of CAN 2.0A and B standards - Standard Frame Format or Extended Frame Format for sending measurement results - manual polling of measurement values possible via Remote Transmission Request (RTR) |
||
L6-OPT-SDC |
Star-Delta-Conversion Minimum requirement LMG600 with at least 3 power channels of the same type |
||
L6-OPT-EVT |
Event Triggering:
find more information here triggering on crossing voltage or current thresholds recording of 16 tracks with up to 4 million values each |
||
L6-OPT-HRM |
Harmonic analysis up to max. 400th order (2.000th order with interharmonics) of U, I, P, Q and S, fundamental 3 ... 1200 Hz, up to 150 kHz (A1 channel) resp. 15 kHz (B1 channel) or 10 kHz (C1 channel) with anti-aliasing filter, customizable settings for the detection of interharmonics |
||
L6-OPT-FLK | Flicker meter according to EN61000-4-15 | ||
L6-OPT-SMV |
Smart Vision Smart add-on functions for the convenient evaluation of measurements The package includes: - Painter: screenshots can be enriched with valuable additional information directly in the GUI before saving - Env Var Watcher: script-controlled visual watchdog as part of a custom menu |
||
L6-OPT-SPV |
Sample Value Analysis Module for LMG600 Software** for continuous and gapless streaming of sample values on 16 tracks at a rate of 10 kS/s (up to 1.2 MS/s under optimal conditions), furthermore: - display of sample recordings in ZLR format - FFT analysis of sample values |
||
L6-OPT-MSD-320 |
Mass Storage Device for Measurement Results (320 GB) Internal mass storage device for long-time recording of measurements (capacity 320 GB) Some space is used for the system. |
* Note: power analyzer has to be equipped with at least three channels of same type for 3-phase measurements
** System requirements:
- Operating system: Windows 7/8/10 (32/64 bit)
- Hard drive: software: min. 50 MB, data: approx. 20 MB per minute of measurement/phase
- RAM memory: min. 2 GB
- Processor: min. 2 GHz, dual-core
- Interfaces supported: Gbit-Ethernet
LMG500 Accessories
Order No. | Product Description |
L50-Z00 | LMG500 manual, German or English |
L50-Z01 | 19"-Mounting kit for LMG500 |
L50-Z04 | Carrying case for LMG500 and accessories (1-4 channels) |
L50-Z05 | Carrying case for LMG500 and accessories (5-8 channels) |
L50-Z13 |
Cable for coupling (DSP extension modul possibly necesary, refer to L50-O10) using a LMG500 for channels 5-8 instead of the extension chassis LMG500-E |
L50-Z14 |
Adapter for LMG500 to connect sensors and current clamps terminating with HD15-plug HD15 to 4mm measuring inputs and DSUB9 sensor identification / supply, especially for L45-Z06, -Z10, -Z16, -Z26, -Z28, -Z29 |
L50-Z18 |
Adapter for incremental speed sensor onto LMG500 measuring channel (I-Sensor input) Pulses converted to analog voltage with +/-sign indicating sense of rotation short response time for graphical presentation to analyse extremely dynamic processes |
L50-Z19 |
Adapter to synchronize on fundamental frequency using a xA:1A current clamp (to be ordered separately), with settable low pass Filter 200Hz - 20kHz |
L50-Z318 |
RS232 - Ethernet - converter, 10/100Mbit external adaptor, all connectors will fixed at the LMG, power supply from LMG |
LMG450 Accessories
Order No. | Product Description |
L45-Z00 | LMG450 manual, German or English |
L45-Z01 | 19"-Mounting kit for LMG450 |
L45-Z02 | Carrying / tilting handle bar for LMG450 |
L45-Z04 |
Carrying case for LMG450 and accessories Plastic foam material inside, outside material Aluminum, lockable, dimensions 25cm x 49cm x 38cm |
L45-Z09 | Adapter BNC to HD15 for isolating current sensors with voltage output; but no EEPROM |
L45-Z13 |
LMG450/500 master-slave cable, length 1m connection of 2 pcs. LMG450 via Sync inputs for simultaneous measuring of more than 4 phases Possible couplings: LMG450 <-> LMG450 LMG450 <-> LMG500 (1-8 phase) LMG500 (1-8 phase) <-> LMG500 (1-8 phase) |
L45-Z18 |
Adapter for incremental speed sensor onto LMG450 measuring channel (HD15 sensor input) Pulses converted an analog voltage with +/- sign indicating sense of rotation Short response time for graphical presentation to analyse extremely dynamic processes |
L45-Z22 |
Adapter safety plug to HD15 for isolating current sensors with current output up to 1,2Apk; EEPROM for storage of scaling |
L45-Z318 |
RS232 - Ethernet - converter, 10/100Mbit external adaptor, all connectors will fixed at the LMG, power supply from LMG |
SSU4 |
Supply unit for 1 to 4 pcs. PSU600 sensors and L45-Z29, for use with LMG instruments |
LMG-Z-AMP | Artificial starpoint simulation for 3p-3w-systems |
L5-Z03 |
Cable for coupling of process signal interfaces (analogue and digital) between two LMG450 and/or LMG95 (option L45-O3, L95-O3), exchange of measuring values for further computation with formula editor, e.g. calculation of efficiency |
L5-IOBOX-S |
Adapter (also for DIN rail mount) from 25pol. SUB-D connector to screw cage connection for conductor cross sections up to 1,5mm x mm incl. 2m cable for connecting adapter with one processing signal interface |
L5-IOBOX-F |
Adapter (also for DIN rail mount) from 25pol. SUB-D connector to screw cage connection for conductor cross sections up to 1,5mm x mm incl. 2m cable for connecting adapter with one processing signal interface |
LMG95/95e Accessories
Order No. | Product Description |
L95-Z00 | LMG95 manual, German or English |
L95-Z01 | 19"-Mounting kit for LMG95 |
L95-Z02 | Carrying / tilting handle bar for LMG95 |
L95-Z03 | Safety claw grip type C, 1 set=4 pcs. 2 pcs. in red, 2 pcs. in black, 20A/1000 |
L95-Z04 | Carrying case for LMG95/95e and accessories |
L95-Z06 |
HF-summing current transformer with burden resistor for interference free current measurements on discharge lamps |
L95-Z06-HV |
HF-summing current transformer with burden resistor, standard safety connectors replaced by special high voltage cable, open on both sides, due to insulation (2kV) reasons (for interference free current measurements on e.g. discharge lamps) |
L95-Z07 |
Adapter LMG95 external shunt input for the use of hall sensors L45-Z28, -Z29 and compensated current clamp L45-Z406 HD15 female to 2x 4mm safety plug, D-SUB9 cable for supply from LMG95 aux. supply |
L50-Z318 |
RS232 - Ethernet - converter, 10/100Mbit external adaptor, all connectors will fixed at the LMG, power supply from LMG |